Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 71
Model IT8960-150-2500
Rated value
(0
40
)
0.3V/250A 3.0V/2500A
Constant voltage
mode
Range 0.1~18V 0.1~150V
Resolution 1mV 10mV
Accuracy ±(0.05%+0.05%FS) ±(0.05%+0.05%FS)
Constant current
mode
Range 0~250A 0~2500A
Resolution 10mA 100mA
Accuracy ±(0.1%+0.1%FS) ±(0.2%+0.2%FS)
Constant
resistance mode
*1
Constant power
Mode *3
Range 60KW
Resolution 1W
Measuring range
Read-back
voltage
Range 0~18V 0~150V
Resolution 1mV 10mV
Accuracy ±(0.025%+0.025%FS) ±(0.025%+0.025%FS)
Read-back
current
Range 0~250A 0~2500A
Resolution 10mA 100mA
Accuracy ±(0.1%+0.1%FS) ±(0.2%+0.2%FS)
Read-back power
*2
Range 60KW
Resolution 1W
Accuracy ±(0.2%+0.3%FS)
Protection range
≒60.6KW
≒275A ≒2750A
≒157V
Overtemperature
protection
≒85℃
Short circuit
Current (CC)
≒275A ≒2750A
Voltage (CV) 0V 0V
Resistance
(CR)
≒1.2mΩ ≒1.2mΩ
≒300KΩ
24U*2
*1.The voltage/current input is no less than 10%FS (FS indicates the full
scope).
*2.The scope of read-back resistance is
(1/(1/R+(1/R)*0.01%+0.08),1/(1/R-(1/R)*0.01%-0.08)).
*3.The voltage/current input is no less than 10%FS.