Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 72
Model IT8960-600-2400
Rated value
(0
40
)
0.52V/240A 5.2V/2400A
Constant voltage
mode
Range 0.1~60V 0.1~600V
Resolution 1mV 10mV
Accuracy ±(0.05%+0.05%FS) ±(0.05%+0.05%FS)
Constant current
mode
Range 0~240A 0~2400A
Resolution 10mA 100mA
Accuracy ±(0.1%+0.1%FS) ±(0.2%+0.2%FS)
Constant
resistance mode
*1
Constant power
Mode *3
Range 60KW
Resolution 1W
Measuring range
Read-back
voltage
Range 0~60V 0~600V
Resolution 1mV 10mV
Accuracy ±(0.025%+0.025%FS) ±(0.025%+0.025%FS)
Read-back
current
Range 0~240A 0~2400A
Resolution 10mA 100mA
Accuracy ±(0.1%+0.1%FS) ±(0.2%+0.2%FS)
Read-back
power *2
Range 60KW
Resolution 1W
Accuracy ±(0.2%+0.4%FS)
Protection range
≒60.6KW
≒264A ≒2640A
≒630V
Overtemperature
protection
≒85℃
Short circuit
Current (CC)
≒264A ≒2640A
Voltage (CV) 0V 0V
Resistance
(CR)
≒2.2mΩ ≒2.2mΩ
≒1MΩ
37U*2
*1.The voltage/current input is no less than 10%FS (FS indicates the full
scope).
*2.The scope of read-back resistance is
(1/(1/R+(1/R)*0.01%+0.08),1/(1/R-(1/R)*0.01%-0.08)).
*3.The voltage/current input is no less than 10%FS.