Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 73
Model IT8960-1200-1200
Rated value
(0
40
)
0.72V/120A 7.2V/1200A
Constant
voltage
mode
Range 0.1~120V 0.1~1200V
Resolution 10mV 100mV
Accuracy ±(0.05%+0.05%FS) ±(0.05%+0.05%FS)
Constant
current
mode
Range 0~120A 0~1200A
Resolution 10mA 100mA
Accuracy ±(0.1%+0.1%FS) ±(0.2%+0.1%FS)
Constant
resistance mode
*1
Constant power
Mode *3
Range 60KW
Resolution 1W
Measuring range
Read-back
voltage
Range 0~120V 0~1200V
Resolution 10mV 100mV
Accuracy ±(0.025%+0.025%FS) ±(0.025%+0.025%FS)
Read-back
current
Range 0~120A 0~1200A
Resolution 10mA 100mA
Accuracy ±(0.1%+0.1%FS) ±(0.2%+0.1%FS)
Read-back
power *2
Range 60KW
Resolution 1W
Accuracy ±(0.2%+0.3%FS)
Protection range
≒60.6KW
≒132A ≒1320A
≒1250V
Overtemperatur
e protection
≒85℃
Short circuit
Current (CC)
≒132A ≒1320A
Voltage (CV) 0V 0V
Resistance (CR)
≒6mΩ ≒6mΩ
≒2MΩ
37U*2
*1.The voltage/current input is no less than 10%FS (FS indicates the full
scope).
*2.The scope of read-back resistance is
(1/(1/R+(1/R)*0.01%+0.08),1/(1/R-(1/R)*0.01%-0.08)).
*3.The voltage/current input is no less than 10%FS.