6 Preventive Maintenance
The tables below summarize when and how the different items of the SeapiX system shall
be maintained – with typical values.
Important
Please note that harsh environmental conditions can increase the maintenance tasks and
shorten the periodicity.
Caution: Always perform the maintenance tasks requested. Otherwise, it could impact the
SeapiX operation as well as its warranty.
SAU ANTENNA CLEANING
Clean the SAU front face using vinegar-type liquid
and a scraper: remove seaweeds, shells, ...
Caution
While scraping the stainless-steel part, be careful
when approaching the cross - clean it carefully as
the black rubber part is fragile.
5 mn to check,
2 hours to change
Inspect the anodes and change them if necessary
Check the witness anode on the SAU front face:
• if its integrity is > 30%: no action.
• if it is worn out (integrity ≤ 30%), change the
witness anode then change the anode located on
the rear side of the SAU:
> Take new anodes from the spare parts.
[witness anode]
[main anode]
> Unscrew each anode.
> Replace it by a new one.
> Screw it again.