SeapiX – Operation Manual
SSD-C-1302 Ed. A – 01/2020 79
SAU ANTENNA AND TRANSDUCER CABLE
If SAU maintenance operation with transducer cable
disconnection:
• Grease the connectors with Molykote 44 Medium
(or Novagard Versilube G624) before mating.
A layer of grease corresponding to
approximately 1/3 of the socket depth should be
applied to the female connector.
All sockets should be completely sealed, and a
transparent layer of grease left visible on the
connector face.
• After greasing, fully mate the male and female
connectors and remove any excess grease from
the connector joint.
Clean the filter on the ITU front face:
• unclip and remove the filter cover.
• Remove the filter and dust it with a brush.
• Clip the cover.