Page 32
ENGLISH
Jandy
®
, JXi
™
Gas-Fired Pool & Spa Heater
|
Installation & Operation Manual
8.3.5 To Revert Heater Control Back to Local Heater User Interface
To revert the heater back to Standalone without
disconnecting the RS-485:
• Make sure the pool heater is OFF.
• Press and hold MENU, then the POOL and SPA
buttons for 5 seconds to access Service Setup mode.
NOTE: The display will revert back to OFF 1 minute after the last key press.
• Press Up or Down to display REMOTE.
• Press MENU, REMOTE OFF (default) is displayed.
• Use Up or Down to scroll through the Remote
options until STANDALONE is displayed, then press
MENU to select.
• Press POOL or SPA to exit Service Setup mode.
Section 9. Operating Instructions
Follow the instructions outlined below to start the heater.
Refer to the Lighting and Shutdown Instructions label on the
inside lid panel of the heater. See Figure 22
All questions should be directed to technical support at
800.822.7933. Additional information can be found at
www.jandy.com.
WARNING
Ifyoudonotfollowtheinstructionsbelowexactly,areorexplosion
may result, causing property damage, personal injury or loss of life.
9.1 Important Safety Information
Read Before You Start:
• This appliance does not have a pilot light. It
is equipped with an ignition device, which
automatically lights the heater. Do NOT try to light
the burners by hand.
• BEFORE OPERATING, smell all around the
appliance for gas. Be sure to smell next to the oor
because some gas is heavier than air and will settle
on the oor.
9.1.1 What To Do If You Smell Gas
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the re department.
• Use only your hand to switch on or off the gas
control switch. Never use tools.
• If the gas control switch appears broken or will not
move, don’t try to repair it, call a qualied service
technician. Force or attempted repair may result in
re or explosion.
• Do not use this appliance if any part has been under
water. Immediately call a qualied service technician
to inspect the appliance and to replace any part of the
control system which has been under water.
9.2 First-Time Start-Up Procedure
WARNING
Vent pipes and heater tops get hot! These surfaces can cause serious
burns. Do not touch these surfaces while the heater is in operation.
Do not use this heater if any part has been under water. Immediately call
aqualiedservicetechniciantoinspecttheheaterandreplaceanypart
of the control system and any gas control which has been under water.
Should overheating occur or the gas supply fail to shut off, turn off
the manual gas control valve to the heater.
Do not attempt repairs on the gas controls or appliance. Tampering
is dangerous and voids all warranties
• Conrm that pool water is owing normally through
the pool system and equipment.
• If it is a new pool or spa installation, operate the lter
pump with the heater off long enough to completely
clean the water. This will remove any installation
residue from the water.
• Clean the lter before starting the heater.
• Start the heater in either Pool or Spa mode. See Figure 22.
• Start the heater. See Figure 22.
• When the heater starts, conrm there is adequate
water ow. See Section 5 for details.