External Control (I/O / Fieldbus) 51 DESKTOP ROBOT JR3000
6.8
Program Number Error and Changing Program Numbers via
Load at Start
This chart shows when [Administrative Settings Mode] [Change Program Number] [I/O-SYS]
is set to [Valid], and when [All Program Common Settings] [I/O Settings] [Program Number
Switching Method] is set to [Load at Start (I/O-SYS)]. When loaded number has no program, a
program number error will occur.
#sysOut8 Position Error
#sysOut7 Emergency Stop
#sysOut6 Error
#sysOut5 Running
#sysOut4 Program Number Error
#sysOut3 Program Number ACK
#sysOut2 Robot Stopped
#sysOut1 Ready for Start
#sysIn12 Temporary Stop
#sysIn11 Last Work
#sysIn4 – 10 Program Number
#sysIn3 Program Number Load
#sysIn2 Free
#sysIn1 Start
30 msec MIN 30 msec MIN
Program Run
Time