- 98 - Orion - 324501H
FR
DEEN
7.10-
Programming the « Standby » time delay
This procedure is realized by the transmitter with buttons
B1
,
B2
and
«On/Off» button.
The receiver does not need to be powered up
Only transmitters equipped with «On/Off» button allow the
user to view or to modify the duration of the «Standby»
function temporization.
1
Simultaneously press and hold buttons
B1
and
B2
then press the «On/Off» button
on the transmitter; keep the three buttons pressed for 1 second, then release the 3
buttons.
Va
and
Vb
transmitter LEDs come on steady,The transmitter is waiting for a
programming choice (this waiting time lasts 4 seconds, after, the transmitter switches
itself off).
2
Press
B2
button to enter in «Standby function time» mode
Vb
LED indicates the current duration :
1 fl ash, off, 1 fl ash etc... = 4mn
2 fl ashes, off, 2 fl ashes etc... = 15mn
3 fl ashes, off, 3 fl ashes etc... = 60mn
4 fl ashes, off, 4 fl ashes etc... = infi nite time (function is deactivated)
Only on OREV and OREL transmitters :
5 fl ashes, off, 5 fl ashes etc... = 30s
3
Press
B2
to modify the duration, each pressure on the button increments the
duration..
4
Once the desired duration is selected, press the «on/off» button to validate your
choice. The transmitter saves the changing.
électronique
+-
B1 B2
B3 B4
B2B1
«On/Off»
Button
Va Vb
«On/Off»
Button
électronique
B1 B2
B3 B4
B1 B2
VbVa
DRAFT a