EasyManua.ls Logo

JohnBean B9800 - Page 82

Default Icon
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82
Description:
Compensating for residual unbalance left in the main shaft.
To save balancing of the main shaft by drilling out material or by adding balance weights, the residual unbalance of the
main shaft is determined and compensated for (subtracted) in all subsequent measurement runs.
To compensate for the residual unbalance of the main shaft on a machine without power clamping device carry out the
following steps:
IMPOTANT! DO NOT USE CONES FROM OTHER BALANCERS MODELS
1. Remove wheel adaptor from main shaft.
2. Activate adjustment function C84.
3. Close the wheel guard and start the measurement run.
The residual unbalance of the main shaft is determined in an extended measuring run.
Comments: Complete this calibration with C88
C85 Copy content of serial EEPROM (EEP) from IBP to optoencoder
Options:
0 : No action
1 : Copy from Integrated Display EEP to opto EEP.
Special function: None
Description: To make sure the content is not overwritten by mistake, fi rst set display from 0 to 1 by using the
option selection.
Then the copying operation is started by pressing the Acknowledgment key.
Once copying has been completed, the machine is started again automatically.
Comments: None
C86 Copy content of serial EEPROM (EEP) from optoencoder to IBP
Options:
0 : No action
1 : Copy from optoencoder EEP to Integrated Display EEP.
Special function: None.
Description: To make sure the content is not overwritten by mistake, fi rst set display from 0 to 1 by using the
option selection.
Then the copying operation is started by pressing the Acknowledgment key.
Once copying has been completed, the machine is started again automatically.
Comments: See C85

Table of Contents