FORM 160.54-O1
143
JOHNSON CONTROLS
2
SLOT
NO.
DESCRIPTION
2849 ACC: Surge Map Count
2850 ACC: Surge Type
2857 ACC: Surge Map Point Count
2858 ACC: Surge Map Delta P/P
2859 ACC: Surge Map Output Frequency
2860 ACC: Surge Map PRV Position
2861 Filter: Is Filter Installed
2862 Filter: Is Operation Inhibited
2863 Filter: Is Filter Running
2864 Filter: Is Precharge Contactor Closed
2865 Filter: Is Supply Contactor Closed
2866 Filter: Phase Rotation
2867 Filter: Motor HP
2868 Filter: Supply kVA
2869 Filter: Total Power Factor
2870 Filter: DC Bus Voltage
2871 Filter: Heatsink Temperature
2872 Filter: L1 - L2 RMS Voltage
2873 Filter: L2 - L3 RMS Voltage
2874 Filter: L3 - L1 RMS Voltage
2875 Filter: L1 - N Peak Voltage
2876 Filter: L2 - N Peak Voltage
2877 Filter: L3 - N Peak Voltage
2878 Filter: L1 Total Harmonic Distortion
2879 Filter: L2 Total Harmonic Distortion
2880 Filter: L3 Total Harmonic Distortion
2881 Filter: L1 RMS Filter Current
2882 Filter: L2 RMS Filter Current
2883 Filter: L3 RMS Filter Current
2884 Filter: L1 RMS Supply Current
2885 Filter: L2 RMS Supply Current
2886 Filter: L3 RMS Supply Current
2887 Filter: L1 Total Demand Distortion
2888 Filter: L2 Total Demand Distortion
2889 Filter: L3 Total Demand Distortion
2890 Filter: Maximum Total Harmonic Distortion
SLOT
NO.
DESCRIPTION
2891 Filter: Maximum Total Demand Distortion
8192 Oil: Pump Pressure
8193 Oil: Sump Pressure
8194 Oil Seal Lube: Is Control Enabled
8195 Oil Seal Lube: Time To Next Lube
8196 Oil Seal Lube: Time Left
8197 VSOP: Speed Command
8198 VSOP: Control Mode
8199 VSOP: Manual Command Frequency
8200 VSOP: Is Pulldown In Effect
8201 VSOP: Pulldown Time Remaining
8202 VSOP: Target Setpoint
8203 VSOP: Pressure Setpoint
8204 VSOP: Control Period
8205 Refrigerant Level: Is Control Enabled
8206 Refrigerant Level: Position
8207 Refrigerant Level: Is Valve Closing
8208 Refrigerant Level: Is Valve Opening
8209 Refrigerant Level: Control Mode
8210 Refrigerant Level: Is Pulldown In Effect
8211 Refrigerant Level: Pulldown Time Remaining
8212 Refrigerant Level: Target Setpoint
8213 Refrigerant Level: Setpoint
8214 Refrigerant Level: Period
8215 Refrigerant Level: Proportional Limit Close
8216 Refrigerant Level: Proportional Limit Open
8217 Refrigerant Level: Rate Limit Close
8218 Refrigerant Level: Rate Limit Open
8221 HSTB: Oil Drain Temperature (Before C.MLM.01.03)
8222 HSTB: Is Solenoid Installed
8223 HSTB: Is Solenoid On
8224 HSTB: Proximity Position
8225 HSTB: Proximity Differential
8226 HSTB: Proximity Reference Position
8280 Stall Detector Board output voltage
8281 VGD open
8282 VGD close
8317 Stall DC Pressure Voltage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls YORK YK MaxE and is the answer not in the manual?

Johnson Controls YORK YK MaxE Specifications

General IconGeneral
BrandJohnson Controls
ModelYORK YK MaxE
CategoryChiller
LanguageEnglish

Related product manuals