16 www.jouleuk.co.uk | www.joule.ie
Technical Specification
Modul-AIR & Green Comfort - Technical Specifications:
SPECIFICATIONS UNIT
CONFIGURATION
SOLO AQUA ALL-E Green Comfort
Mains connection
P+N230V
~50Hz
+10%-6%”
P+N230V
~50Hz
+10%-6%”
P+N230V
~50Hz
+10%-6%”
P+N230V
~50Hz
+10%-6%”
Fuse a 32 16 32 16
Max. power consumption W 620 620 6370 80
Max. absorbed electrical
power heat pump
W 620 620 620 N/A
Max. power consumption
instantaneous
W N/A N/A 3450 N/A
Max. absorbed power excl.
DHW Tank element
W N/A N/A 2300 N/A
Average electrical consumption
power heat pump
W 300 300 300 N/A
IP Class X2 X2 X2 X2
Max. working pressure kPa 300 300 300 300
Cord type
3 core cable
flex (1m)
3 core cable
flex (1m)
3 core cable
flex (1m)
3 core cable
flex (1m)
PERFORMANCE
Max. supply temperature C 60 60 60 65
Max. delivered thermal power kWh 1.71 1.71 1.71 3.5
COP (20 °C-45 °C) 5.0 5.0 5.0 N/A
Reheater power kW N/A N/A
max 4.5 kW
+ 15%
N/A
REFRIGERANT
Refrigerant Type R134a R134a R134a N/A
Refrigerant content g 580 580 580 N/A
GWP Value 1430 1430 1430 N/A
C02 equivalent kg 830 830 830 N/A
DIMENSIONS AND WEIGHT
Height mm 700 700 700 700
Width mm 500 500 500 298
Depth mm 500 500 500 493
Weight kg 58 55 60 20