Use a liing tool if moving the Modul-AIR upstairs.
Transport & Handling
Handling Instructions
Care must be taken when transporting, storing and
installing the Heat Pump.
The Modul-AIR unit is delivered securely packaged
in a polystyrene sandwich. Care should be taken
when transporting the Heat Pump ensuring that
the unit is not damaged by impact
The Heat Pump must remain in the upright position
during transport.
Do not remove the protective packaging until the
Heat Pump unit has reached its final location. This
will help protect the Heat Pump from damage.
For transport, e.g. via a stairs, the Heat Pump may
be tilted for a maximum of 15 minutes up to a
maximum angle of 45 degrees.
The Heat Pump can weigh up to 60kg. At least two
people are required to li the unit at all times .
The Heat Pump must be stored in a dry area
and always stored upright on a level base. The
temperature in the storage room should be
between 5°C and 50°C. The humidity may be a
maximum of 85%, non-condensing
The unit must never be dropped during storage or
handling
The installation area should be free from frost.
The Modul-AIR unit must only be installed on a
plumb level wall with the required load bearing
capability.
Installation, servicing, maintenance and repair
must be carried out by a competent person.