8.2.3 Setting a Serial Port
Verify the setting of the serial port of this equipment and perform initial setting by using the [Serial Port]
dialog.
Synchronizing setting
The [Serial Port] dialog enables common setting items and individual setting items for RADAR, ECDIS,
and Conning (called a task station individually). Once common items are set in any of the task stations,
RADAR, ECDIS, and Conning, the settings are reflected (synchronized) in other task stations.
By setting common items in the state where all the task stations are active, the common setting items
are synchronized in all the task stations.
8.2.3.1 Displaying the [Serial Port] dialog
When you select [System Configuration] in the first classification pane and [Serial Port] in the second
classification pane, the [Serial Port] dialog is displayed in the edit/result pane.
8.2.3.2 [Diagnosis] lamp light colors
The [Diagnosis] lamp indicates the diagnosis result on whether or not the sentence of the sensor
specified for each serial port has been received successfully and the status of ISW/MTR/Serial OPU.
Lit in red: Data not received.
Lit in green: Data is receiving.
Lit in orange: In diagnosis (before decision).
No color: Serial port is disabled.