9-43  Section 9 Maintenance & Inspection 
 
 
 
 
 
 
9.10  Recovery of the Images in the C Drive 
 
 
 
The backup power supply (DC power supply, etc.) of the equipment must be 
connected when recovery of the C drive image is performed. If the power supply 
stops during recovery, an equipment activation fault occurs, causing an accident.
 
 
Do not turn off the power supply during recovery of the C drive image.   
Otherwise, equipment malfunction occurs, possibly causing an accident.
 
 
The operating system (OS) of this equipment runs on the C drive. 
The contents of the C drive including the images are stored in the D drive. 
When the OS operation on the C drive becomes unstable, the images in the C drive can be written 
back from the D drive.
 
 
Note 
When the images in the C drive are written back, the information relating to C-MAP is cleared. 
After writing back of images, re-register the database and licence of C-MAP and perform update 
as required. (Required when the equipment has the ECDIS function or chart radar function 
 
The flow of writing back of images in the C drive is as follows. 
 
Start this equipment with the OS in the D drive 
"9.9.1 Starting the equipment with the OS in the D drive" 
Execute the SSD recovery tool. 
"9.9.2 Executing the SSD recovery tool" 
Start the equipment with OS in the C drive. 
"9.9.3 
Starting the equipment with the OS in the C drive (Software 
Re-set C-MAP.