129 
Chapter 9    MAINTENANCE AND CHECK
9.6  TROUBLE SHOOTING 
As this radar equipment includes complicated circuits, it is necessary to request a specialist engineer for 
repair or instructions for remedy if any circuit is defective. 
There are also troubles by the following causes, which should be referred to in checking or repair work. 
 
  Poor Contact in Terminal Board of Inter-Unit Cables. 
  Poor contact in terminal board. 
  The cable end is not fully connected, that it, contacted with earthed another terminal. 
  Disconnected cable wire. 
  Poor Contact of Connector with in Unit. 
 
 
9.6.1  SPECIAL PARTS 
 
Location  Parts No.  Name  Type  Code  Manufacture 
NKE-1066 V101  Magnetron  M1624  5VMAA00120  New JRC 
NKE-2044 V101  Magnetron  MSF1421B 5VMAA00092 New JRC 
NKE-2044 A101  Circulator  FCX68R 5AJIX00027 Orient Microwave 
NKE-2044  A102  Diode Limiter  NJS6930  5ATBT00006  New JRC 
 
 
9.6.2    CIRCUIT BLOCK TO BE REPAIRED 
 
JMA-1032 
Location  Circuit Block  Type  Remarks 
Scanner Motor unit  H-7BDRD0053  
Scanner 
Transmitter/ receiver 
 
Microwave unit 
NZT-1066 
Include Magnetron and
Chassis 
Display Unit  LCD Panel unit  NZP-2256 
Include Process Circuit 
CDC-1433 
 
JMA-1034 
Location  Circuit Block  Type  Remarks 
Scanner Motor unit  H-7BDRD0052A  
Scanner Modulation circuit CME-397     
Scanner  2ft Radar Antenna  NAX-96  Include Horn Antenna 
Scanner Transmitter/ receiver NZT-2044 
Include Magnetron 
Scanner Receiver  NRG-242   
Display Unit  LCD Panel unit  NZP-2256 
Include Process Circuit 
CDC-1433