Chapter 1    INSTALLATION 
13 
1.3.3   MOUNTING RACK AND MAST FOR THE SCANNER 
 
If it is considered that sufficient installation height cannot be provided when the scanner is installed directly on 
the roof of the wheelhouse, use a mounting rack or radar mast (Fig. 1-3-3). 
Normally, when the scanner installation height is less than 2 meters from the roof of the wheelhouse, provide a 
mounting rack assembled at an angle frame to install the scanner. When the scanner installation height is 2 m 
or higher from the roof of the wheelhouse, provide a cylindrical radar mast to install the scanner. 
Consider the convenience of the service staff who take care of installation, maintenance, adjustment and 
repair of the scanner by providing adequate footholds to the mounting rack and the radar mast. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig. 1-3-3 
 
 
1.3.4    SCANNER AND THE SURROUNDING STRUCTURAL 
OBJECTS 
 
When installing the scanner, select a location where there are the fewest structural objects in the surrounding 
area so that false images which interfere with target detection will not be generated by signal reflection from 
other scanners, deck structures, and cargo   
Only as a guide, note that structural objects should not exist within the range of the vertical beam width 
(Fig. 1-3-4). 
 
Vertical beam width of X-band: Approx. 25° (+/-12.5° when the height of the radiating section is 0°). 
 
 
 
 
 
 
 
 
 
 
Fig. 1-3-4 
 
Fig. 1-3-4