EasyManua.ls Logo

JRC JMA-1030 Series - 12.4 General Specifications

JRC JMA-1030 Series
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 12 SPECIFICATIONS
139
12.4 GENERAL SPECIFICATIONS
(1) Class of Emission P0N
(2) Display Color Raster Scan
(3)Display capability WVGA (800x480dots) Screen
(4) Screen 7-inch Color LCD with touch sensor (resistance film type)
(5) Range Scale 0.0625, 0.125, 0.25, 0.5, 0.75, 1.5, 3, 6, 12, 24, 48NM
(48 NM: only 2feet type scanner is available)
User can add 1, 2, 4, 8, 16, and 32NM
(32 NM: only 2feet type scanner is available)
(6) Range Resolution Less than 30m
(7) Minimum Detective Range Less than 40m
(8) Range Accuracy Less than 1% of the maximum distance of the range scale
in use or less than 15m whichever is larger.
(9) Bearing Accuracy Less than ±1°
(10) Bearing Indication RM: Head-up, North-up, Course-up
TM: North-up, Course-up
(11) Ambient Condition
Standards IEC60945 Ed.4.0
Temperature
Scanner Operation: -25 to +55°C / Storage: -25 to +70°C
Other Unit except Scanner Operation: -15 to +55°C / Storage: -15 to +70°C
Relative Humidity +40°C, 93%
Vibration 2 to 13.2 Hz, amplitude±1mm
13.2 to 100 Hz, 0.7 G
Velocity of the wind 100kn
Waterproof/dustproof Scanner IP26
Display unit IP55
(12) Power Supply Input DC 10.8-31.2V (DC12-24V-10%+30%)
(13) Power Consumption Approx. 50W (NKE-1066/NKE-2044).
Maximum: 50W
(NKE-1066: SP1, NKE-2044: LP2 transmitting)
(14) Pre heat time Approx. within 1min30sec.
(15) Display unit Refer to Display unit Specifications
(16)Inter-unit Cables Using common scanner connecting cable CFQ9924-10
Standard Length 10m
Maximum cable length 30m (option)

Table of Contents

Related product manuals