Chapter 12    SPECIFICATIONS 
141 
12.5.2  SCANNER (NKE-2044) SPECIFICATION 
(1) Dimensions   Height 280mm×Diameter of radome 620mm 
(2) Mass    Approx. 10kg 
(3) Polarization      Horizontal (antenna length 2 feet) 
(4) Directional Characteristic  Horizontal Beam Width (-3dB)  4° 
Vertical Beam Width (-3dB)  25° 
Side lobe Level     -21dB or less (less than ±10° from the main lobe) 
(5) Rotation        Approx. 27rpm (16/20/24/27/30/36/42/48rpm can be set) 
(6) Transmitting Frequency  9410±30MHz 
(7) Peak Power      4 kW 
(8)Transmitting Tube      Magnetron [MSF1421B] 
(9) Pulse width/ Repetition Frequency (Bandwidth) 
SP1: 0.08μs/4000 Hz (Wide 20MHz) 
SP2: 0.08μs/2250 Hz (Wide 20MHz) 
SP3: 0.13μs/1700 Hz (Wide 20MHz) 
MP1: 0.25μs/1700 Hz (Middle 6MHz) 
MP2: 0.5μs/1200 Hz (Narrow 3MHz) 
LP1: 0.8μs/750 Hz  (Narrow 3MHz) 
LP2:1.0us/650Hz   (Narrow 3MHZ) 
(S: Short pulse, M: Middle pulse, L: Long pulse)
 
(10) Range Information    0.0625NM  SP1 
0.125NM SP1 
0.25 NM   SP1 
0.5 NM    SP1 / MP1 
0.75 NM   SP2 / MP1 
1.5 NM    SP2 / MP1 / MP2 
3 NM    SP3 / MP1 / MP2 
6 NM    MP2 / LP1/ LP2 
12 NM    MP2 / LP1/ LP2 
24 NM    LP2 
48 NM    LP2 
(11) Duplexer        Circulator + Diode Limiter 
(12) Front End Module    MIC   
(13) IF Frequency      60MHz 
(14) IF AMP    Log Amplifier (Gain: more than 90dB) 
(15) Overall Noise Figure    6dB (Average)   
(16) Tuning    Manual/Auto