– 57 –
(4) Simplified program command list
The command list and parameter list to be used for simplified program function are provided.
4
1
2
3
3
0
1
2
or
End
DELy
And
OR conditional branch
Stitching count OR
conditional branch
Completion
AND conditional branch
Delay
Enable
Enable
Enable
Enable
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
Enable
Enable
Disabled
Disabled
iH.1 to 75
iL.1 to 75
iH.1 to 75
iL.1 to 75
iH.1 to 75
iL.1 to 75
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
iH.1 to 75
iL.1 to 75
iH.1 to 75
iL.1 to 75
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
oH.1 to 32
oL.1 to 32
iH.1 to 75
iL.1 to 75
Skip destination step
No. (Sn)
Skip destination step
No. (Sn)
Skip destination step
No. (Sn)
Skip destination step
No. (Sn)
Skip destination step
No. (Sn)
Skip destination step
No. (Sn)
1 to 25
1 to 25
Delay time (d)
Delay time (d)
Delay time (d)
0 : Waiting for input until
conditions are met
1-999 X 1mS
0 : Waiting for input until
conditions are met
1-999 X 1mS
When any one of the conditions specified in the input setting is met (OR input), transition to the next step is
executed.
When input conditions are not met and the delay time is exceeded, jump to the step specified with the skip
destination step number is executed.
A command is disabled when the delay time is 0. Other than that, transition to the next step is executed after
lapse of the delay time.
When all the conditions specified in the input setting are met (AND input), transition to the next step is executed.
When input conditions are not met and the delay time is exceeded, jump to the step specified with the skip
destination step number is executed.
Initial value
54STiA
Stitching count AND
conditional branch
Enable Enable
1 to 25
Stitching count
(C)
0: Command disabled
(1 to 999 stitches)
When all the input setting conditions are met within the setting range of the stitching count setting (AND input),
jump to the step specified with the skip destination step number.
After the predetermined stitching count ends, transition to the next step is executed.
The machine speed can be set.
An operation is always performed when the delay time is 0. Other than that, an operation is performed at specified
speed within the delay time, and the speed command is cancels after lapse of the delay time.
Actual rotation speed will not be equal to or less than the setting value specified in function setting No. 35,
minimum rotation speed, and also will not equal to or more than the setting value specified in function setting
No. 96, maximum rotation speed.
The limit value of the maximum speed of the machine can be specified.
The speed limit is always enabled when the delay time is 0. Other than that, the specified speed limit is enabled
within the delay time, and the speed limit command is canceled after lapse of the delay time.
Actual speed limit will not be equal to or less than the setting value specified in function setting
No. 35, minimum rotation speed, and also will not equal to or more than the setting value specified
in function setting No. 96, maximum rotation speed.
Jump between specified steps repeats up to the specified repeat number of times.
When the setting value is 0, loop is executed endlessly.
(Caution) Do not execute nested input of this command.
When any one of the input setting conditions are met within the setting range of the stitching count setting (OR
input), jump to the step specified with the skip destination step number.
After the predetermined stitching count ends, transition to the next step is executed.
65STio
Enable Enable
1 to 25
Stitching count
(C)
0: Command disabled
(1 to 999 stitches)
76JUMP
Jump repeat counter
Enable Disabled
—
—
—
Disabled
Disabled
—
—
Disabled
—
Jump
(Sn)
1 to 25
Repeat count
value
(r)
0: Unlimited
(1 to 999)
—0 to 999
Delay time
(d)
0: Delay time disabled
0 to 999 X 1mS
—0 to 999
Delay time
(d)
0: Delay time disabled
0 to 999 X 1mS
(X 10sti/min)
(X 10sti/min)
— on/off
Delay time
(d)
0: No delay
1 to 999 X 1mS
The command is executed without the delay time when the delay time is 0. Other than that, LSW is disabled
within the specified delay time, and LSW input is enabled after lapse of the delay time.
Delay time
(d)
0: No delay
1 to 999 X 1mS
Thread trimming is executed.
The command is disabled when the delay time is 0. Other than that, the thread trimming command is provided
within the specified delay time.
Thread trimming output is delayed.
The command is executed without the delay time when the delay time is 0. Other than that, the thread trimming
delay command is provided within the specified delay time, and canceled after lapse of the delay time.
0:
1-999 X 1mS
—
on/off
Delay time
(d)
0: No delay
1 to 999 X 1mS
Delay time
(d)
0: No delay
1 to 999 X 1mS
Up position stop is executed. Even if speed is specified by other command, the command is ignored.
The command is executed without the delay time when the delay time is 0. Other than that, the up position stop
command is enabled within the specified delay time, and disabled after laps of the delay time.
Delay time
(d)
0: No delay
1 to 999 X 1mS
When the command is executed, positive rotation is performed to make the needle move to the up position if it
is at the down position or to make the needle move to the down position if it is at the up position. Even if speed
specified by other command, the command is ignored.
The command is executed without the delay time when the delay time is 0. Other than that, the command is
enabled within the specified delay time, and disable after lapse of the delay time.
Delay time
(d)
Stop is executed by applying brake in a reverse rotation from the angle specified in function setting
No. 107, reversing brake start angle.
The command is executed without the delay time when the delay time is 0. Other than that, the command is
enable within the specified delay time, and disabled after laps of the delay time.
1 to 25
0: No delay
1 to 359 degree
After lapse of the specified angle, transition to the next step is executed. When all the conditions for input are met
before lapse of the specified angle (AND input), transition to the skip destination step No. is executed. (A reference
angle is an angle from the point departing from the up position for a machine head using a belt and an angle from
the upper needle dead point for a direct motor type machine head.)
After lapse of the specified angle, transition to the next step is executed. When any one of the input conditions is met
before lapse of the specified angle (OR input), transition to the skip destination step No. is executed. (A reference
angle is an angle from the point departing from the up position for a machine head using a belt and an angle from
the upper needle dead point for a direct motor type machine head.)
Sewing machine stop is executed.
Transition to the next step is immediately executed when the delay time is 0. Other than that, transition to the next
step is executed after lapse of the specified time.
The reverse feed stitching switch is set to on/off.
The command is executed without the delay time when the delay time is 0. Other than that, the back tack output is
set to "on" within the specified time, and is set to "off" after lapse of the specified time.
The presser lifting switch command is set to on/off.
The command is executed without the delay time when the delay time is 0. Other than that, the presser lifting output
is set to "on" within the specified time, and is set to "off" after lapse of the specified time.
Initialization of the step of a specified program number is executed.
The step of a specified program is forcibly returned to the initial step.
17 16 AnGo
Angle OR
conditional branch
Enable Enable
1 to 25
0: No delay
1 to 359 degree
——
——
——
——
——
Delay time
(d)
0: No delay
1 to 999 X 1mS
—
on/off
Delay time
(d)
0: No delay
1 to 999 X 1mS
0: No delay
1 to 999 X 1mS
—
on/off
Delay time
(d)
0: Disabled
1 to 999 X 1mS
21 20 rEST
Program reset
Enable Disabled
—
Program No. (Sn)
1 to 4
Disabled
—
Enable Disabled
on/off information
(on/off)
20 19 FL
FLsw command
(Presser lifting output)
Enable Disabled
on/off information
(on/off)
19 18 bT
BTsw command
(Reverse feed
stitching output)
Angle
(A)
18 17 SToP
Stop command
Enable Disabled Disabled
Angle
(A)
Enable Disabled Disabled
16 15 AnGA
Angle AND
conditional branch
Enable Enable
15 14 rSW Rsw command
Enable Disabled Disabled
14 13 HS
Needle up/down command
Enable Disabled Disabled
13 12 UP
Up stop command
Enable Disabled Disabled
12 11 TinH Tswinh command
Enable Disabled
on/off information
(on/off)
11 10 TrM
Thread trimming command
10 9 LinH Lswinh command
98LiMi
Speed limit command
87SPEd
Rotation speed command
Enable Disabled Speed
(S)
Enable Disabled Speed limit
(S)
Enable Disabled
on/off information
(on/off)
No.
Function code
Command
Output setting Setting range Setting range
Setting range Setting range RemarksInput setting Parameter 1 Parameter 2
Abbreviation