EasyManuals Logo

JUKI SC-922 Engineer's Manual

JUKI SC-922
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
– 1 –
1. SPECIFICATIONS
Supply voltage Single phase 100 to 120V 3-phase 200 to 240V Single phase 200 to 240V
Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz
Operating temperature range Temperature : 0 to 40°C Temperature : 0 to 40°C Temperature : 0 to 40°C
Operating humidity range Humidity : 90% or less Humidity : 90% or less Humidity : 90% or less
Power consumption 310VA 310VA 310VA
Mass 3 kg 3 kg 3 kg
2. OUTLINE
(1) Features
1) Voltage changeover function of single phase 100 to 120V/3-phase 200 to 240V is provided.
The control box with voltage changeover function can be used either for single phase 100 to 120V or for 3-
phase 200 to 240V by replacing the power cord up to the power switch and changing the voltage changeover
connector inside the box.
In addition, it can be used for single phase 200 to 240V.
2) By using CP-180, CP-18 the sewing management information such as output display, etc. can be used.
3) The conventional JUKI optional devices should be used upon confirmation of distributor.
4) By using the flash ROM for CPU, the future version-up can be adapted.
5) Connection of the motor unit (M51N) allows SC-922 to be used for a (belt) drive machine head.
* The power consumption is a reference value when LU-1510N-7 is used as a sewing machine.
The power consumption varies depending on a sewing machine head to be selected.

Table of Contents