4 Configuration parameters
80
Configuration Digital signal name
Unit
(external
analog inputs and
counters)
Configuration
Analog inputs
External input
1—36
External counter 1—2
Addit’l parameters
Unit
5 characters
%
v Chapter 3.8 “Text entry”
Decimal place
(external
analog inputs and
counters)
Configuration
Analog inputs
External input
1—36
External counter 1—2
Addit’l parameters
Decimal place
Automatic,
X.XXXX,
XX.XXX,
XXX.XX,
XXXX.X (with analog inp.)
XXXXX. (with counter)
Automatic: representation
with maximum resolution
Integrator
time base
(external
analog inputs)
Configuration
Analog inputs
External input
1—36
Addit’l parameters
Integr.
time base
Off,
Second,
Minute,
Hour,
Day
Time base for the
integrator. If the time base
is switched off, the
integrator indication is
suppressed in the report.
v Chapter 2.6 “Integrator”
Integrator unit
(external
analog inputs)
Configuration
Analog inputs
External input
1—36
Addit’l parameters
Integr. unit
5 characters v Chapter 2.6 “Integrator”
Parameter Value/selection Description
Parameter Value/selection Description
Digital signal name Configuration
Digital signal name
Logic input 1 7
Alarm group 1 6
Combination alarm
Logged in
Error
Modbus flag
External input
1—6
CF card plugged in
Stolen CF card
Int. mem. al./via CF
Int. mem. al./serial
Memory alarm CF
card
7 characters
LogInp 1 7
Al.Gr.1 6
Alarm
Logged in
Error
MB flag
ExtInp1 6
CF card
CF card
Mem. al.
Mem. al.
Mem. al.
v Chapter 3.8 “Text entry”