Table 1: FRUs in an ACX7348 Router
FRU Type
Power supply modules (PSMs) Hot-insertable and hot-removable
Fan trays Hot-insertable and hot-removable
Air lter Hot-insertable and hot-removable
Roung Engines Hot-pluggable
Flexible PIC Concentrators (FPCs) Hot-pluggable
We recommend that you take the FPCs oine before
removing them. You can take FPCs oine by using the
request chassis fpc slot
slot-number
oine command.
Opcal transceivers Hot-pluggable
ACX7348 Router Component Redundancy
The following hardware components provide redundancy on ACX7348 routers:
• Roung Engines—A redundant system on an ACX7348 consists of two Roung Engines that are
available as eld-replaceable units (FRUs). One Roung Engine funcons as the primary and the
other funcons as the backup.
• Power supply modules (PSMs)—You can install up to two PSMs on ACX7348 routers to provide full
power, 1+1 redundancy to the device. Each PSM provides power to all components in the router. If
one PSM fails, or if you remove one PSM, the second PSM balances the electrical load without
interrupon.
9