EasyManua.ls Logo

Juniper AP32 - Page 65

Juniper AP32
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 12: Troubleshoot AP Disconnecon Issues
(Connued)
LED Color Blink Paern Issue Steps to Troubleshoot
"uptime":
707675.367648
}
3. Check the rewall logs
to see whether any
policy is blocking the
hps://ep-
terminator.mistsys.net
/about URL.
Blinking yellow two mes The switch or AP is
experiencing a Layer 2
issue.
1. Run a cable test to
verify that the cable
connected to the AP is
working correctly.
2. Check whether the
switch port connected
to the AP learns the
MAC address of the
AP.
3. Check for any eth0
errors on the switch
port.
4. Change the cable and
switch port and verify
that the AP powers
on.
5. If you have a working
AP, swap it with the
faulty AP. Check
whether the issue
persists.
NOTE: If your APs are
already installed and
you cannot swap any
AP, skip this step.
60

Table of Contents

Related product manuals