Removing the Device
•
Powering Off a QFX3500 Device on page 143
•
Removing a QFX3500 Device from a Rack or Cabinet on page 145
Powering Off a QFX3500 Device
NOTE: Use the following procedure to turn off power on a QFX3500 device
that is in standalone mode, a member in a QFX Virtual Chassis, or a spine
device in a Virtual Chassis Fabric. QFX3500 devices that are Node devices
in a QFabric system running OS Junos release 14.1 or later must use a different
procedure and CLI to ensure there is no traffic loss. See Powering Off an
Existing QFabric Node Device.
Before you power off a QFX3500 device:
•
Ensure that you have taken the necessary precautions to prevent electrostatic discharge
(ESD) damage. See “Prevention of Electrostatic Discharge Damage” on page 198.
•
Ensure that you do not need to forward traffic through the device.
Ensure that you have the following parts and tools available to power off the device:
•
An ESD grounding strap
•
An external management device such as a PC
•
An RJ-45 to DB-9 rollover cable to connect the external management device to the
console port
To power off a QFX3500 device: