EasyManua.ls Logo

Juniper QFX3500 - Chapter 15 Removing the Device; Powering off a QFX3500 Device

Juniper QFX3500
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 15
Removing the Device
Powering Off a QFX3500 Device on page 143
Removing a QFX3500 Device from a Rack or Cabinet on page 145
Powering Off a QFX3500 Device
NOTE: Use the following procedure to turn off power on a QFX3500 device
that is in standalone mode, a member in a QFX Virtual Chassis, or a spine
device in a Virtual Chassis Fabric. QFX3500 devices that are Node devices
in a QFabric system running OS Junos release 14.1 or later must use a different
procedure and CLI to ensure there is no traffic loss. See Powering Off an
Existing QFabric Node Device.
Before you power off a QFX3500 device:
Ensure that you have taken the necessary precautions to prevent electrostatic discharge
(ESD) damage. See “Prevention of Electrostatic Discharge Damage” on page 198.
Ensure that you do not need to forward traffic through the device.
Ensure that you have the following parts and tools available to power off the device:
An ESD grounding strap
An external management device such as a PC
An RJ-45 to DB-9 rollover cable to connect the external management device to the
console port
To power off a QFX3500 device:
143Copyright © 2017, Juniper Networks, Inc.