Table 25 on page 57 describes the DC power specifications for a QFX3500 device.
Table 25: DC Power Specifications for a QFX3500 Device
SpecificationsItem
Minimum operating voltage: –40 VDC
Nominal operating voltage: –48 VDC
Operating voltage range: –40 VDC through 72 VDC
DC input voltage
7 A maximum at nominal operating voltage (–48 VDC)DC input current rating
250 WTypical power consumption
385 WMaximum power consumption
Related
Documentation
DC Power Supply for a QFX3500, QFX3600, or QFX3600-I Device on page 37
DC Power Supply LEDs on a QFX3500, QFX3600, or QFX3600-I Device on page 40
Grounding Cable and Lug Specifications for a QFX3500 Device
For installations that require a separate grounding conductor to the chassis, the device
must be adequately grounded before power is connected to ensure proper operation
and to meet safety and electromagnetic interference (EMI) requirements. To ground a
QFX3500 device, connect a grounding cable to earth ground and then attach it to the
chassis grounding points.
WARNING: The device is pluggable type A equipment installed in a
restricted-access location. It has a separate protective earthing terminal
provided on the chassis in addition to the grounding pin of the power supply
cord. This separate protective earthing terminal must be permanently
connected to earth ground for installations that require a separate grounding
conductor to the chassis.