EasyManuals Logo

Juniper SRX340 User Manual

Juniper SRX340
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #92 background imageLoading...
Page #92 background image
Protocols=Allow All
d. Click OK to save changes, and select Commit>Commit to apply the configuration
and other pending changes (if any).
4. To use the port on the Mini-PIM, you must also set security policies. Select the following
settings:
a. Select Configure>Security>Security Policy.
b. Select Global Options > Policy Options.
c. Set Policy Action: Default Policy Action=Permit-All.
d. Click OK to save changes, and select Commit>Commit to apply the configuration
and other pending changes (if any).
Using the CLI
To perform basic configuration for the 1-Port T1/E1 Mini-PIM (for the T1 interface) and to
configure network interfaces for the services gateway with the CLI:
1. Verify that the T1/E1 interface is installed on the device:
show chassis hardware
2. Verify the status of the interface:
show interfaces terse
3. Assign the port an IP address:
For T1 interfaces:
set interfaces t1-1/0/0 unit 0 family inet address interface address/destination prefix
For E1 interfaces:
set interfaces e1-1/0/0 unit 0 family inet address interface address/destination prefix
4. Add or select a security zone; for example, Trust:
For T1 interfaces:
set security zones security-zone trust interfaces t1-1/0/0.0 host-inbound-traffic
system-services all
For E1 interfaces:
set security zones security-zone trust interfaces e1-1/0/0.0 host-inbound-traffic
system-services all
5. Add or select security zones for host inbound traffic protocol options:
For T1 interfaces:
Copyright © 2017, Juniper Networks, Inc.74
SRX300 Series and SRX550 High Memory Gateway Interface Modules Reference

Table of Contents

Other manuals for Juniper SRX340

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX340 and is the answer not in the manual?

Juniper SRX340 Specifications

General IconGeneral
Firewall Throughput3 Gbps
Maximum Concurrent Sessions256, 000
Memory4 GB
Redundant Power SuppliesNo
Operating Temperature32°F to 104°F (0°C to 40°C)
Humidity10% to 90% non-condensing
Storage8 GB