Table 32: Chassis Component Alarm Conditions on SRX3400 and SRX3600 Services Gateways (continued)
Alarm
SeverityRemedyAlarm Condition
Chassis
Component
YellowInsert power supply into
empty slot.
A power supply has been
removed from the chassis.
PWR (Power
supplies)
RedReplace failed power
supply or power entry
module.
A power supply has a high
temperature.
RedCheck power supply input
connection.
A power supply input has
failed.
RedCheck power supply
output connection.
A power supply output has
failed.
RedReplace failed power
supply.
A power supply has failed.
RedWhen two AC power
supplies are installed,
insert one power supply
into an odd-numbered slot
and the other power
supply into an
even-numbered slot.
Invalid AC power supply
configuration.
RedWhen two DC power
supplies are installed,
insert one power supply
into an odd-numbered slot
and the other power
supply into an
even-numbered slot.
Invalid DC power supply
configuration.
RedDo not mix AC and DC
power supplies. For DC
power, remove the AC
power supply. For AC
power, remove the DC
power supply.
Mix of AC and DC power
supplies.
RedInstall an additional power
supply.
Not enough power supplies.
183

Table of Contents

Other manuals for Juniper SRX3600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX3600 and is the answer not in the manual?

Juniper SRX3600 Specifications

General IconGeneral
Maximum Firewall Throughput20 Gbps
Maximum VPN Throughput10 Gbps
Maximum Concurrent Sessions1, 000, 000
Memory16 GB
Power SupplyDual AC or DC power supplies
Operating Temperature32°F to 104°F (0°C to 40°C)
Interfaces8 x 10/100/1000BASE-T ports, 4x 10GBASE SFP+ ports

Related product manuals