Issue the CLI show chassis fpc command to check the status of installed IOCs and NP-IOCs. As shown
in the sample output, the value Online in the column labeled State indicates that the IOC or NP-IOC is
functioning normally:
user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 35 43 0 1024 4 27
1 Online 34 43 0 1024 4 27
2 Online 34 43 0 1024 4 27
3 Empty
4 Online 40 43 0 1024 4 27
5 Empty
6 Online 39 43 0 1024 4 27
7 Empty
8 Empty
9 Empty
10 Online 35 43 0 1024 4 27
11 Online 36 43 0 1024 4 27
12 Empty
Using a question mark (?) gives you a listing of the various options for the command:
user@host> show chassis fpc ?
Possible completions:
<[Enter]> Execute this command
<fpc-slot> FPC slot number (0..12)
detail Display detailed output
pic-status Show Physical Interface Cards installed in FPC
| Pipe through a command
To view information about a particular card in the chassis, use the fpc slot option:
user@host> show chassis fpc 6
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
6 Online 35 42 0 1024 4 27
For more detailed output, add the detail option. The following example does not specify a slot number,
which is optional:
user@host> show chassis fpc detail
190