Figure 68: Removing a CFM (IOC Shown, Other CFMs Similar)
g036055
9. Place the CFM on the antistatic mat. If you are not reinstalling a replacement CFM into the emptied
slot within 30 minutes, install a blank panel over the slot to maintain proper airflow in the card cage.
If you need to replace IOC transceivers, see “Replacing SFP, SFP+, and XFP Transceivers on the SRX3600
Services Gateway” on page 203; otherwise, continue with step 10.
10. Carefully align the sides of the replacement CFM with the guides inside the chassis.
11. Slide the CFM into the slot until you feel resistance, and then press the CFM's faceplate until it engages
the connectors.
12. Tighten the captive screws on the left and right of the CFM faceplate.