NOTE: The services gateway must be running Junos OS Release 10.2 or later to use the SCM.
When running earlier Junos OS Releases, the services gateway does not properly recognize it.
For more information about configuring and managing chassis clusters, see the chapter “Chassis Cluster”
in the Junos OS Security Configuration Guide.
•
SRX Clustering Module for SRX3400 and SRX3600
•
Power requirement: 35 W maximum
•
Weight: 2.0 lb (0.9 kg)
Description
•
Junos OS Release 10.2 and laterSoftware release
NoneCables and
connectors
•
SRX1400: Not Applicable
•
SRX3400 and SRX3600: Slot RE1 only.
Supported Slots
The SCM is a cold-swap-only module. You must power-off the services gateway before
removing or installing the SCM.
Swapping
ONLINE Button–The ONLINE button on the SCM front panel does not perform any
function.
Controls
OK/FAIL LED, one bicolor
•
Off–One or more of the following conditions apply:
•
The services gateway is not powered on.
•
The services gateway is still in the process of either booting or shutting down.
•
The services gateway is not configured for chassis clustering.
•
Steady Green–The services gateway is configured for chassis clustering, and the SCM
is operating normally.
•
Blinking Green–The SCM is initializing (preparing to come online) or is preparing to go
offline.
•
Red–The SCM has failed and is not operating normally.
LEDs
48