No.
Item Reference picture/drawing Procedure
2-27
20
e
Cleaner assembly
<Removal>
1)Remove the washer (W2)
2)Take out the
e
cleaner assembly.
<Attaching>
1)Reverse the removal procedure.
2)Activate the cleaner (loading) and ensure that the
cleaner contacts the drum normally. (Make sure that
the cleaner rotation sound is heard.)
<When an active head cleaner assembly is dis-
assembled>
After the active head cleaner assembly has been dis-
assembled and assembled, the following adjustment
is required to restore the pressure of contact of the
cleaner to the drum.
1)Rotate screw
Å
fully clockwise until it is stopped,
then rotate it counterclockwise by 2.5 turns. (The
clamping torque is 4.9 x 10
-4
N m/0.5 kgf cm or
less)
2)Rotate screw
ı
fully clockwise until it is stopped,
then rotate it counterclockwise by 0.5 of a turn.
(The clamping torque is 4.9 x 10
-4
N m/0.5 kgf cm
or less)
3)Activate the cleaner (perform loading) and confirm
that the contact between the claw, cleaner and
drum is normal. (The rotation sound of the cleaner
should be audible now.)
4)If the cleaner does not work normally, rotate screw
ı
clockwise by 1/8 turn and check the operation
again.
Fig. 2-7-18(c)
43
W2