3-18
No. Item
Measuring
instruments &
Input signals
Mode
Measuring point
(*)
Adjustment parts
(-)
Adjustment level
(+)
Adjustment procedure
1
PB switching
point
adjustment
• Alignment tape
MC-1, color bar
PB
Automatic adjust-
ment
+ Adjustment is per-
formed automati-
cally so that the tim-
ings of HID and SPA
signals are as shown
below.
(1) Click [PB Switching Point (Auto)].
(2) Click [OK] to start automatic adjustment.
(3) Message “Complete” is displayed when the
adjustment has completed successfully. If it is
unsuccessful, the message “Adjustment
failed” is displayed; try adjustment again.
3.7.7 Servo Circuit Adjustment
HID
SPA
126 ± 10µs
3-17
“Complete” message
“failed” message