Operating instructions
• TheoperatingmodeNIGHTisautomaticallyactiveifnoprogramswitchisconnectedto
the control unit or if all contacts are open.
• Inordertoavoidthatachangeoftheoperatingmodesetsoffanimmediatedooraction,
1 second will be retarded (de-bounced).
• Incaseswhereakey-operatedselectorswitch(oratimer)isconnectedincombination
with a D-BEDIX, the key-operated selector switch has top priority. In this condition any
change of the operating mode made through the D-BEDIX is memorized and will be
implemented upon revocation (release) or removal of the key-operated selector switch.
For switching over to the operating mode NIGHT (by means of the key-operated selec-
tor switch or the timer), the terminal inputs 8 + 9 need to be connected among each
other and the respective element must be connected.