Basis: QS-CL P.05.05.113.4
Maintenance for pedestrian doors
Check
Clean
Grease
Adjust
Generalcondition x
Freedoormovement(manually) x x
Doorguides/guidewayrails x x x
Doorsealingjoints x x x
Sidepanels/protectionwings x x
Coverings/hinge-typecovers x x
Checktightttingofthescrewsandnuts x
Clean the installation
2
x x
Drive mechanism
Drivemechanism x x x
HoldingpowerinCLOSEDposition x
Transmission elements such as:
toothedbelt,atbelt,cables,rodsorchains x x x
Carryingrollers/counter-pressurerollers,runningcarriages x x x
Carrierrails x x x
Open/Closedpositions x x
Electricalconnections x
Controlfunctions x x
Programswitch(BEDIS,BEDiX,etc.)checkallthepositions x
Emergencybattery x
Emergency opening (pull out both power plugs of the ANTE‘s)
1
x
Alltheexistingcontrolelementssuchas:
sensor,radar,key-operatedswitch,contactcarpet,etc. x x x
Reversing/stoppingmechanism x x x
Doorlocking/manualunlockingmechanism x x x x
Mechanicalemergencyopening x x
Monitoringswitch x x x
Lightbarrier/Presencedetector x x
Existingadditionalsafetyelements x x x
Minimum escape way width
1
x x
Stickers/ratingplates x x
1
Only for redundant drive mechanisms
2
KABA Gilgen cleans all the elements of the installation provided this is necessary for the function of the instal-