Amanuallockingisconsideredtobee.g.alockinginstalledinthewingprolewhose
lockingbolttowardstheoor.InsettingtheDIPswitch3toON,thedrivemechanismis
informed about the manual locking.
• SelectoperatingmodeNIGHT,doorcloses,lockmanuallocking.
• DoorissetonoperatingmodeNIGHT,unlockmanuallocking,slidethedoorwingopen,
after termination of the hold-open time NIGHT the door closes automatically, optionally
lock again or select operating mode AUTOMAT.
If DIP-Switch 3 is set to ON, no pressing in the operating mode NIGHT (in order to enable
a manual sliding the door wing open).
• Ifanopeningcommandisactivatedforalockedmanuallocking,thecontrolunitrecog-
nises this and stops the door.
• WhenswitchingfromoperatingmodeNIGHTtoanotherone,aslowandshortopening
detects whether manual locking has really been unlocked.
• WhenswitchingfromoperatingmodeNIGHTtoanotheroneorafteractivatingthekey
push-button, the wing stops 140 mm before reaching the open position (to avoid forgot-
ten stuck keys to break off).
• AfteraKeycommandintheoperatingmodeNIGHT,theslidingwingscovertherst
65 mm at slow speed (= in order to check if the door is unlocked). If the manual locking
is locked, an error is displayed.
Note:
By means of the manual locking mechanism, the travel distance (per wing)
can be limited to 65 mm. If a Key command is given, the door waits in this
position until the Key command is de-energized, upon which the door is
closed (pharmacy locking method). No error is displayed.
When using a rubber cable for the emergency opening, the DIP-Switch 5 must be set to
ON.
The rubber cable is tested in the setting-up procedure, after the door has reached the
CLOSED position. The door is unlocked. If a correctly set rubber cable is available, the
doorwillopen.Ifthedoorisopenedapprox.10cminmax.10seconds,themovementis
motor stopped and closed again.
If the rubber cable is too slack or incorrectly adjusted, an error will be displayed. For in-
stallations with D-BEDIX and an emergency battery the door will continue to function nor-
mally (while the error will still be displayed). For installations without D-BEDIX, the wings
will move to the Open position. Switching over to the operating mode NIGHT, however, is
still possible.