0639-990-21---30j_2010.07.indd
SLA
LED
uC
OKx
SI
0639-990/22j
Page 19 of 46
Operating instructions
 
 
 
• Doorstopsimmediatelyandisunlocked.
• Ifdoorisclosedandlocked,thelockedpositionismaintained,thepushpressureis
cancelled.
• Ifarubbercableisavailableandthedoorisnotlocked,slidingwingsareopened
by the rubber cable.
 
see chapter „parameter settings“.
 
• Incombinationwithanopeningcommand(Key,OKI,OKA).Theslidingwing(s)
open until set reduced OPEN position.
• Reducedopeningmustthelatestbesetwiththeopeningsignal.
• Reducedpositionismotorheldwhenrecognisingtherubbercable.
 
• Wheninterrupted,twolightbarriersinvertthemotion.
• Bymeansofmotorcurrentmonitoringand/orstandstillrecognitionareverseof
motion can also be set off.
• Fromtheobstacleposition,thenextclosingmoveismadeslowly.
• Lightbarriers/presencesensingdevicesaretestedduringtheopeningmove.The
test is repeated until success. Until then, the door remains open.
 
• Bymeansofmotorcurrentmonitoringand/orstandstillrecognitionastopisactiva-
ted.
• Ashortdisengagingmoveinclosingdirectioniscarriedoutprovidedthereisno
opening command or reverse. Otherwise the door is stopped for 1 second.
• Afterwardsitisopenedatcreepagespeed.
 
• Unlocksandopensthedoor.Afterwardsthehold-opentimeNIGHTisawaiteduntil
the door closes and locks.
• Keycarriesoutawake-up.
 
• Dooropens,awaitssethold-opentimeandcloses.
 
• Dooropens,awaitssethold-opentimeandcloses.
Denition,Remarks
Flashes in 1 second-time = normal operating state.
Lights up = there is at least one mistake.
Lights up = at least one control element (OKA, OKI, Key) is acti-
ve.
Lights up = at least one safety element (SIR1, SIR2, Not-Stopp) is
active.
Function
error
Opening
signal
Light barrier/
Emergency
stop