Operating instructions
 
Warning:
Electrocution hazard! Before working on any live elements, pull out the
mainsplugaswellasanyexistingplugoftheemergencybatteryrespective-
ly switch off the main installation switch!
If a malfunction occurs which might be detrimental to the safety of the users,
and which cannot be eliminated without delay, the operator must be informed
and if required the installation shall be taken out of operation. The installation
must be repaired as soon as possible.
Note:
Every troubleshooting procedure which is carried out must be entered into
the control booklet!
A reset activates a new setting-up procedure which is carried out only in the operating
mode AUTOMAT.
Note:
The setting-up procedure is only carried out in the mains-powered mode,
whereas no setting-up is possible in the emergency battery mode because of
the restricted battery power. The control unit STERE is automatically swit-
ched off.
 
Press reset push-button during at least 1
second with a tool (e.g. paper clip).
Note:
Alternatively, to activate the
reset function, push simultane-
ously (min 1 second) operating
modes MANUAL and EXIT.
 
Press reset push-button during at least
1 second.