TECHNICAL DESCRIPTION MULTICAL
®
401
5512-091 GB/02.2008/Rev. J1
68
Print certificate Starts printing the calibration certificate.
Preset Starting values for input A and input B.
Programming Starts programming the meter. All data displayed will be transmitted to the meter.
R
Read meter Reads the meter’s setting. All the meter’s data are transmitted to the display.
Save Customer Stores a setting in the database.
Serial No. The meter’s serial number.
Start test This command is used to start the automatic verification sequence.
T
Target date The yearly target date which most often is the district heating company’s billing date.
On target date all relevant registers are stored for later reading. The format is MM-DD,
where MM=1…12 and DD = 1…28.
Tariff limits The tariff limits determine when the tariff registers TA2 and TA3 must accumulate
energy parallel with the energy reading. The tariff limits are only used with E=1, 2, 3 or
5.
Test initial Registers the value before verification.
Time The computer’s actual time, which is transmitted to the meter at programming.
TL2 Tariff limit 2 indicates the start conditions for TA2.
TL3 Tariff limit 3 indicates the start conditions for TA3.
Type No. The meter’s type number contains information on power supply, data module, sensor
module, pick-up unit and language on the front label.