2100-900-01 Rev. D / September 2011 I-1
Index
Numerics
2-wire ........................................................3-4
2-wire, RTD measurements .....................3-8
3-wire, RTD measurements .....................3-9
3-wire, RTD temperature ..........................3-9
4-wire ........................................................3-4
4-wire, RTD measurements ...................3-10
A
AC filter, defaults ......................................4-4
AC measurements ....................................3-2
AC, filter ....................................................4-4
Accessories ..............................................1-5
Accuracy ...........................................4-4, 4-6
ADC, set ...................................................4-2
Addenda, manual .....................................1-3
Adjusting the handle .................................2-2
Annunciators, display ...................2-22, 2-23
Application programs ............................. B-30
Application, Visual C++ sample ............. B-35
Auto Gain .................................................4-2
Auto trigger .............................................4-14
Auto Zero ..................................................4-2
Automatic trigger delay ...........................4-19
Average, Min/Max ....................... 4-23, B-17
Average, moving ......................................4-5
Average, repeating ...................................4-5
Averaging digital filter ...............................4-5
B
Basic measurement functions ..................3-2
Beeper ....................................................4-32
Beeper, defaults .....................................4-32
Boolean parameters ................................ B-5
C
Calibration ..............................................4-41
Calibration, view information ..................4-41
Capacity, memory ..................................4-33
Command format ..................................... B-2
Command syntax .................................... B-3
Command terminators, SCPI .................. B-4
Command, CONFigure ............................ B-7
Command, math operation ............ 5-7, B-14
Command, MEASure? ............................ B-6
Command, measurement configuration .. B-9
Commands, common ...............................5-3
Commands, IEEE-488.2 .........................5-10
Commands, IEEE-488.2 common ........... B-4
Commands, measurement configuration .5-7
Commands, other interface 5-10, B-20, B-22
Commands, remote interface ...................5-3
Commands, SCPI ............................5-2, B-2
Commands, status reporting ..........5-9, B-26
Commands, system-related ...........5-9, B-18
Commands, triggering ....................5-8, B-17
Compliance, IEEE-488 ...........................B-30
Compliance, SCPI ..................................B-28
Configuration, measurement .................... 4-2
Configuration, measurement commands . 5-7
CONFigure command ..............................B-7
Connecting, power ................................... 2-7
Connection, USB ................................... 2-23
Connections ................................... 2-23, 3-2
Connector, USB ....................................... 5-2
Continuity ................................................. 4-8
Continuity, measure ................................. 3-7
Current, measure ..................................... 3-3
D
Damage, Inspection for ............................ 1-4
Data formats, output ................................B-5
dB calculation ......................................... 4-28
dB measurement .................................... 4-28
dB, function ............................................ 4-27
dBm calculation ...................................... 4-29
dBm measurement ................................. 4-30
dBm, function ......................................... 4-29
DC input resistance .................................. 4-7
DC input resistance defaults .................... 4-8
DC measurements ................................... 3-2
Default, factory settings ......................... 2-18
Defaults, AC filter ..................................... 4-4
Defaults, Auto Zero, Auto Gain ................ 4-2
Defaults, beeper ..................................... 4-32
Defaults, DC input resistance .................. 4-8
Defaults, digital filter ................................. 4-5
Defaults, display ..................................... 4-31
Defaults, range ......................................... 4-9
Defaults, resolution .................................. 4-6
Defaults, sensitivity band ....................... 4-35
Defaults, threshold resistance .................. 4-9
Defaults, trigger delay ............................ 4-19
Delay time, trigger .................................. 4-20
Delay, trigger .......................................... 4-19
DEVQUERY ...........................................B-35
Digital filter ............................................... 4-5
Digital filter, defaults ................................. 4-5
Diode, measure ................................ 3-7, 3-8
Discrete parameters .................................B-5
Display .........................................2-21, 4-31
Display keys ........................................... 2-20
Display, annunciators ................... 2-22, 2-23
Display, defaults ..................................... 4-31

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2100 and is the answer not in the manual?

Keithley 2100 Specifications

General IconGeneral
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
Resistance Range100 Ω to 100 MΩ
ContinuityYes
Diode TestYes
Frequency Range3 Hz to 300 kHz
DC Voltage Accuracy0.0035%
DC Current Range100 µA to 10 A
DC Current Accuracy0.05%
AC Current Range100 µA to 10 A
Frequency Accuracy0.01%
Capacitance Range1 nF to 10 mF
Temperature Range-200 °C
ConnectivityRS-232
Type6.5-digit digital multimeter