4. Secure the wire spool in place by closing the wire spool locking cover.
To install the filler wire:
1. Release the filler wire end from the spool and cut off any deformed section so that the end is straight.
Ensure that the filler wire does not spill from the spool when it is released.
2. File the tip of the filler wire smooth.
Sharp edges on the filler wire tip may damage the wire liner.
3. Release the pressure arms to move the feed rolls apart.