X5 FastMig
Operating manual - EN
Water cooler
OFF/Auto/ON
Default = OFF
When ON is selected, the coolant is cir-
culated continually, and when Auto is
selected, the coolant is circulated only dur-
ing welding. TheAuto modeisavailable
only with welding guns supporting the
automatic detection.
Weld data duration
0 ... 30 s, step 1
0 = OFF
Default = 5 s
This defines if and how long theweld data
summary is shown aftereach weld.
Date
Current date
Time
Current time
Language
Available languages
Factory reset
Reset/Cancel
Default = Cancel
Safe wire inch
(with MIG only)
OFF/ON When ON, and thearc doesn't ignite, the
filler wireis fed 5 cm When OFF, 5 m of filler
wireis fed.
Cable calibration
(with MIG only)
Start/Cancel The date and time and thecalibration
information of the previous calibration is
also shown.
Refer to
"Calibrating welding cable" on
page62
for cablecalibration.
VRD
(with MMA and gouging only)
OFF/12V/24V
Default = OFF
Voltage reduction device (VRD) reduces
the open-circuit voltageto maintain below
a certain voltagevalue.
3.3.8 Auto control panel: Applying welding programs
Use the welding program that is in accordance with your welding setup (e.g. welding wire and gas properties).
The use of additional welding programs and Wise features is possible with the X5 FastMig Synergic equipment in MIG
operation mode.
1. Go to the Memory channels view. (Refer to "Auto control panel: Memory channels" on page70 for more inform-
ation.)
2. Enter the actions menu.
3. Select Create channel.
>> A filter view opens.