X5 FastMig
Operating manual - EN
>> Shows the wire feed speed, current and/or voltage (content shown depends on the welding process selec-
ted).
To change the control panel settings and welding parameters, refer to "Manual control panel: Settings" below.
3.2.1 Manual control panel: Settings
To enter and use Settings menu:
1. Press the Settings menu button.
2. Switch between the menu items by turning the control knob.
3. Select a menu item for adjustment by pressing the control knob button.
4. Adjust the parameter value (or other settings value) by turning the control knob.
5. Exit the adjustment dialog by pressing the control knob button again.
Rarely used settings items are hidden by default. Those are available in the advanced settings menu. To enter the
advanced Settings menu, press the Settings button for approx. 5 seconds.
MIG settings
The parameters listed here are available for adjustment with the MIG process.
Parameter Parameter value Description
Pre gas
Min/Max = 0 ... 9.9 s, step0.1 s
0 = OFF
Default = auto
Welding function that starts theshielding
gasflow beforethe arc ignites. This ensures
that themetal does not comeinto con-
tact with air at the start of theweld. Time
value is preset by the user. Used for all
metals, but especially for stainless steel, alu-
minum and titanium.
Post gas
Min/Max = 0 ... 9.9 s, step0.1 s
0 = OFF
Default = auto
Welding function that continues the shield-
ing gas flow after the arc has extinguished.
This ensures that thehot weld does not
come into contact with air after the arc is
extinguished, protecting the weld and also
the electrode. Used for all metals. Especially
stainless steeland titaniumrequirelonger
post gas times.
Creep start level
Min/Max = 10 ... 90 %, step 1 %
Default = auto
The Creep start function defines the wire
feed speed beforethe welding arc ignites,
that is, beforethe filler wire comes in con-
tact with the workpiece. When the arc
ignites, the wire feed speed is automatically
switched to thenormal user-set speed. The
Creep start function is always on.
Touch Sense Ignition
ON/OFF
Default = OFF
Touch Sense Ignition delivers minimum
spatter and stabilizes the arc immediately
after ignition.
© Kemppi
64 1920960 / 2039

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi X5 FastMig Series and is the answer not in the manual?

Kemppi X5 FastMig Series Specifications

General IconGeneral
BrandKemppi
ModelX5 FastMig Series
CategoryWelding System
LanguageEnglish

Related product manuals