X5 FastMig
Operating manual - EN
Pre gas
0.0 ... 9.9 s, step 0.1
0.0 = OFF
Welding function that starts theshielding
gasflow beforethe arc ignites. This ensures
that themetal does not comeinto con-
tact with air at the start of theweld. Time
value is preset by the user. Used for all
metals, but especially for stainless steel, alu-
minum and titanium.
Creep start
10...90 %, step 1 The Creep start function defines the wire
feed speed beforethe welding arc ignites,
that is, beforethe filler wire comes in con-
tact with the workpiece. When the arc
ignites, the wire feed speed is automatically
switched to thenormal user-set speed. The
Creep start function is always on.
Crater fill
ON/OFF When welding with high power, a crateris
usually formed at the end of the weld. The
Craterfill function decreases the welding
power/ wirefeed speed at the end of the
welding job so that the cratercan befilled
using a lowerpowerlevel. With MIG pro-
cess, Craterfill duration, wirefeed speed
and voltagearepreset by the user.
When the wire feed speed is less than 5
m/min, the adjustment stepis 0.05 and
when the wirefeed speed is 5 m/min or
more, the adjustment step is 0.1.
For 1-MIG process, refer to the 1-MIG
parameter table.
- Crater fillduration
0.0 ... 10.0 s, step 0.1
Default = 1.0 s
- Crater fill wire feed speed
0.5 ... 25.0 m/min, step 0.05 or 0.1
Default = 5 m/min
- Crater fill voltage
450A: 10 ... 45 V
500A: 10 ... 50 V
Step0.1 V
Default = 18V
Post gas
0.0 ... 9.9 s, step 0.1
0.0 = OFF
Welding function that continues the shield-
ing gas flow after the arc has extinguished.
This ensures that thehot weld does not
come into contact with air after the arc is
extinguished, protecting the weld and also
the electrode. Used for all metals. Especially
stainless steeland titaniumrequirelonger
post gas times.
Wire feed speed
0.50 ... 25 m/min, step0.05 or 0.1
Default = 5.00 m/min
Wirefeed speed adjustment. When the
wirefeed speed is less than 5 m/min, the
adjustment step is 0.05 and when the wire
feed speed is 5 m/min or more, the adjust-
ment step is 0.1.
Wire feed speed limit min
Min/Max = 0.5 ... 25 m/min, step0.1
Default = 0.5 m/min
Minimumand maximum limits for the wire
feed speed adjustment.
Wire feed speed limit max
Min/Max = 0.5 ... 25 m/min, step0.1
Default = 25 m/min
1-MIG welding parameters
The parameters listed here are available for adjustment only with the 1-MIG process.
Parameter Parameter value Description
© Kemppi
74 1920960 / 2039

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi X5 FastMig Series and is the answer not in the manual?

Kemppi X5 FastMig Series Specifications

General IconGeneral
BrandKemppi
ModelX5 FastMig Series
CategoryWelding System
LanguageEnglish

Related product manuals