X5 FastMig
Operating manual - EN
40
VRD error Open circuit voltageexceeds the VRD limit. Restart the power source. If problempersists, contact
Kemppiservice.
42
High current
in wirefeeder
motor
Theremay betoo much pressure in the wire
feed rolls or dirt in the wire line.
Adjust the feed roll pressure. Clean the wireline. Change
worn parts in the welding gun.
43
Overcurrent in
wirefeeder
motor
Theremay betoo much pressure in the wire
feed rolls or dirt in the wire line.
Adjust the feed roll pressure. Clean the wireline. Change
worn parts in the welding gun.
44
Wirespeed
measurement
is missing
Faulty sensor or wiring in wirefeeder. Restart the welding system. If problempersists, contact
Kemppiservice.
50
Welding pro-
gram error
Required welding program is not installed. Contact Kemppiservice for installing welding programs.
62
Power source
not found
No powersource is connected to thewire
feeder, or connection isfaulty.
Check the controlcable and its connectors.
81
Welding pro-
gram data
missing
Welding programdata has been lost. Restart the power source. If problempersists, contact
Kemppiservice.
244
Internal
memory fail-
ure
Initialization failed (%sub:%device). Restart welding system. If problempersists, contact
Kemppiservice.
250
Internal
memory fail-
ure
Memory communication failed (%sub:%device). Restart welding system. If problempersists, contact
Kemppiservice.
© Kemppi
96 1920960 / 2039