386 Keysight EXG and MXG X-Series Signal Generators User’s Guide
Using Avionics VOR/ILS Softkeys for N5171B/72B and N5181B/82B with Option 302
Using ILS Glide Slope Softkeys
4. Select a <value> from 0 to 10.0 uA and press Enter.
These softkeys set a value for the difference in depth of modulation (DDM)
in uA.
To set the ILS Glide Slope DDM value in percentage (%)
1. Press Aux Fctn > Avionics > ILS Glide Slope
2. Press DDM/SDM
3. Press DDM%
(Default <value> is 0.00%.)
4. Select a <value> from 0 - 99% and press Enter.
These softkeys set a value for the difference in depth of modulation (DDM)
in %. DDM can be expressed either in terms of percentage (%) or as a
modulation index. A DDM of 1% is equivalent to 0.001 DDM.
To set the ILS Glide Slope SDM value
1. Press Aux Fctn > Avionics > ILS Glide Slope
2. Press DDM/SDM
3. Press SDM
4. Select a <value> from 0 to 99% and press Enter.
(Default <value> is 80%.)
These softkeys set the sum of depth of modulation (SDM):
SDM = [AM(90 Hz) + AM(150 Hz)] / 100

Table of Contents

Other manuals for Keysight Technologies N5183B MXG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies N5183B MXG and is the answer not in the manual?

Keysight Technologies N5183B MXG Specifications

General IconGeneral
BrandKeysight Technologies
ModelN5183B MXG
CategoryPortable Generator
LanguageEnglish

Related product manuals