73
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
3 MIN Main reference
Auxiliary reference
A2.02
UP/DN rate
0.01~99.99Hz/s
0.01
1.00
1~9999
A2.03
UP/DN regulating
control
LED unit’s place
0Save reference frequency upon
power outage
1Not save reference frequency
upon power outage.
LED ten’s place
0 Hold reference frequency at
stop
1Clear reference frequency at
stop
1
00
0~11H
A2.04
Jog operating
frequency
0.10~50.00Hz
0.01Hz
5.00
10~5000
A2.05
Interval of Jog
operation
0.0~100.0s
0.1s
0.0
0~1000
A2.06
Skip frequency 1
0.00~300.00Hz
0.01Hz
0.00
×
0~30000
A2.07
Range of skip
frequency 1
0.00~30.00Hz
0.01Hz
0.00
×
0~3000
A2.08
Skip frequency 2
0.00~300.00Hz
0.01Hz
0.00
×
0~30000
A2.09
Range of skip
frequency
0.00~30.00Hz
0.01Hz
0.00
×
0~3000
A2.10
Skip frequency 3
0.00~300.00Hz
0.01Hz
0.00
×
0~30000
A2.11
Range of skip
frequency 3
0.00~30.00Hz
0.01Hz
0.00
×
0~3000
Group A3:Setting curve
A3.00
Reference
frequency
curve selection
LED unit’s place AI1 curve
selection
0Curve 1
1Curve 2
2Curve 3
3Curve 4
LED ten’s place AI2 curve
selection
1
0000
0~3333H