89
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
address
b3.02
Time threshold for
judging
the communication
status
0.0~1000.0S
0.1
0.0S
×
0~10000
b3.03
Delay for
responding to
control PC
0~1000mS
1
5mS
×
0~1000
Group b4:Keyboard parameters
b4.00
Key-lock function
selection
0: The keys on the operation
panel are not locked, and all the
keys are usable.
1: The keys on the operation
panel
are locked, and all the keys are
unusable.
2: All the keys except for the
multi-functional key are unusable.
3: All the keys except for the
SHIFT key are unusable.
4:All the keys except for the RUN
AND STOP keys are unusable.
1
0
0~4
b4.01
Multi-function key
definition
0: Jog function
1: Coast-to-stop
2: Stop in shortest time
3: Switch of input method of
operating command
1
0
0~3
b4.02
Parameter
protection
0: All parameters are allowed
modifying;
1: Only A0.03 and b4.02 can be
modified;
2: Only b4.02 can be modified.
1
1
0~2
b4.03
Parameter
initialization
0: No operation
1: Clear falt information in
memory
2: Restore to factory settings
1
0
×
0~2
b4.04
Parameter copy
0: No action
1
0
×
0~3

Table of Contents