CVS-128/128B Chapter 5 Installation
0093112802-06 5-11
Connection with external equipment
The DC power cable contains the connection cables for external equipment such as navigation
equipment and KODEN GPS sensor.
Color Pin Remark
Red 3 Power +
Black 9 Power -
Orange 6 NMEA TX +
Blue 5 NMEA TX -
White 7 NMEA RX +
Green 8 NMEA RX -
Color Pin Remark
White 2
Sona-Tone
TM
External speaker output
(with ø3.5 stereo jack)
Red 1
Black 11
Yellow 12 Outside power (+)
Gray 4 Outside power (-)
Shield 10
Connection with GPS-20A
After soldering, implement the waterproof and insulation treatment on the connected part with the
self-melting tape.
CVS-128/128B
DC power cable
(CW-264A-2M)
GPS-20A (No Type)
Connecting up without using a
connector
GPS-20A (Type B)
Connecting up using a
connector*
Color Remark Color
Pin
Orange
NMEA TX +
Orange
2
Blue
NMEA TX -
Blue
3
White
NMEA RX +
White
4
Green
NMEA RX -
Green
5
Yellow Outside power (+) Red
6
Gray
Outside power (-)
Black
1
*Optional connector (LTWBD-06PMMP-LC) is necessary.