Chapter 5 Installation CVS-128/128B
5-14 0093112802-06
5.5 Serial Data
Input Data
The sentences of GGA, GLL, HDT, MTV, MWV, RMC, VHW, VTG and ZDA can be received.
The type of NMEA0183 Ver.1.5, Ver.2.0 and Ver.3.0 can be input.
Information Priority Order of Sentence Information Priority Order of Sentence
Latitude,
Longitude
GGA > RMC > GLL Wind Direction MWV
Course VTG > RMC Wind Speed MWV
Heading HDT Date ZDA > RMC
Ground Speed VTG > RMC Time ZDA > GGA
Water Speed VHW Water
Temperature
MTW
Output Data
The sentences of DBT, DPT, GGA, GLL, HDT, MTW, MWV, RMC, TLL, VHW, VTG and ZDA can be
transmitted.
The output is performed in the type of NMEA0183 Ver.2.0. However, the DBT is performed in Ver.1.5.
Sentence Information Sentence Information
DBT Depth MWV Wind Direction, Wind Speed
DPT Depth from the transducer RMC Latitude/Longitude, Course,
Ground Speed, Date
GGA Latitude/Longitude, Time TLL Target Position
GLL Latitude/Longitude VHW Water Speed
HDT Heading VTG Course, Ground Speed
MTW Water Temperature ZDA Date,Time