EasyManuals Logo

Kollmorgen SERVOSTAR 614 User Manual

Kollmorgen SERVOSTAR 614
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #82 background imageLoading...
Page #82 background image
9.3.7 Save Parameters and Restart
You are going to finish setup and you have changed several basic parameters. Depending on the
parameters you changed, two possible reactions can occur:
Configuration parameters changed
A warning appears, that you have to restart the amplifier. This is called "coldstart". Click "YES". The
parameters are saved to the amplifier's EEPROM automatically and a reset command restarts the
amplifier (takes a few seconds). For example, this happens after motor or feedback selection.
Other parameters changed
No warning appears. Parameters are saved in the volatile RAM only. Save the parameters to the
EEPROM of the servo amplifier manually by clicking the symbol in the tool bar. A coldstart
of the amplifier is not necessary.
Reset the amplifier
You can reset the amplifier manually (e.g. in case of an error). Click the icon .
SERVOSTAR
®
601...620 Instructions Manual 81
Kollmorgen
07/2010 Setup

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen SERVOSTAR 614 and is the answer not in the manual?

Kollmorgen SERVOSTAR 614 Specifications

General IconGeneral
BrandKollmorgen
ModelSERVOSTAR 614
CategoryAmplifier
LanguageEnglish

Related product manuals